You are here:Home > Products > MCA Electronics > Scintillator MCAs > AVATAR-F High-Speed Scintillation Digital MCA

AVATAR-F High-Speed Scintillation Digital MCA

Web Editor:Jiechuang Nuclear Instruments │ Published:: 2026-04-17 23:00:23

  AVATAR-F High-Speed Scintillation Digital MCA

  Introduction

  The AVATAR-F High-Speed Scintillation Digital MCA is a product designed for extreme count rate applications. It was developed to solve the problem that in some strong radiation fields, ordinary electronics cannot achieve high count throughput and cannot complete data measurement.

  The system has been completely upgraded and optimized to adapt to high count throughput. Tube-socket integrated design, integrates voltage divider circuit, preamplifier, programmable gain amplifier, digital shaping filter, temperature acquisition and necessary power supply units. While maintaining high count throughput, the overall power consumption is less than 2W, and it can still run in USB powered systems.

  

 

  Product Features

  l Variable gain: 512, 1024, 2048, 4096 channels software adjustable;

  l Reserved clock synchronization interface, synchronization accuracy 12.5ns;

  l Integrated temperature sensor, can perform temperature correction and peak position compensation for detector;

  l Stable and reliable for long-term operation, zero drift less than 1 channel in 72 hours, gain instability less than 0.2% in 72 hours;

  l Zero temperature coefficient: less than 0.2 channels/℃; gain temperature coefficient: less than 0.1%/℃;

  l Multiple communication modes optional: serial port, Ethernet, RS232, RS485, RS422, USB, etc.;

  l Digital pile-up rejection, digital gating, digital baseline restoration;

  l Integrated digital anti-coincidence/anti-cosmic interface, parameters flexible adjustable;

  l Count throughput characteristics:

  With LaBr3 detector, at input count rate of 500Kcps, resolution better than 3%, dead time better than 20%, peak drift better than 0.5%;

  With NaI detector, at input count rate of 200Kcps, resolution better than 7.5%, dead time better than 10%, peak drift better than 1%;

  l Detector high voltage: 0 to +1100Vdc, step 1V;

  l Dimensions: 63mm(diameter)*86mm(length), weight: <300g;

  l Power supply: +5V, power consumption <2W;

  l Operating temperature: -20℃~+55℃

  l One year free hardware warranty, lifetime free software upgrade;

  l All software interfaces open, convenient for user secondary development;

  l Includes basic spectrum analysis software: GammaSense.
      
        Operation Guide
        
       l  AVATAR-F Ultra High Count Throughput MCA - Your New Choice for Data Acquisition_bilibili




Scan the QR code above
Or search in WeChat“Jiechuang Nuclear Instruments” Follow Us
Stay Updated with Latest News

News

  • Silent Gamma Hunter - HPGe Spectrometer in Radioactivity Detection

    In today's increasingly widespread application of nuclear energy and technology, precise identification and quantitative analysis of radionuclei have become core requirements in fields such as environmental protection, nuclear safety regulation, medical diagnosis, and astrophysical research

    VIEW DETAILS
  • BNCT Technology - 90 Years of Development

    Boron Neutron Capture Therapy (BNCT) is a precision radiotherapy technique that uses boron drugs to target and enrich tumor cells, and triggers a neutron irradiation response to accurately kill cancer

    VIEW DETAILS
  • China Nuclear Medicine Development Status

    The first isotope usage training course was established in Xi'an, Shaanxi in 1956, marking the birth of nuclear medicine in China. Since then, nuclear medicine has been integrated into clinical practice and serves patients nationwide

    VIEW DETAILS
  • 2025 China BNCT Project Summary

    BNCT construction projects in mainland China are classified into already operational, pre operational, under construction, and planned projects based on their operational status The pre operational projects in the table include projects that have already conducted or are planned to conduct clinical research

    VIEW DETAILS
  • Infographic - Nuclear Power Plant Environmental Protection

    New standards for radiation protection regulations in nuclear power plants have been released, mainly introducing the content

    VIEW DETAILS
  • Worlds Only! China Achieves New Nuclear Tech Breakthrough

    Independently designed, developed, and built by our country fourth-generation advanced fission nuclear energy system - thorium-based molten salt experimental reactor, Recently, it was built in Wuwei and Gansu, and for the first time, thorium uranium conversion was achieved in the reactor

    VIEW DETAILS

Products

  • JHP-ACM/CS Anti-Compton/Cosmic-Ray HPGe Spectrometer

    high-purity germanium (HPGe)γenergy spectrometer It is the most precise instrument in the field of spectral measurement, widely used in various radiometric measurement sites However, in the measurement of certain environmental samples, the radioactivity of the samples is low and requires the use of an anti cosmic ray anti Compton ray HPGe (High Purity Germanium) gamma energy spectrometer

  • JHP-GE Series HPGe Gamma Spectrometer

    laboratory HPGe (High-Purity Germanium) γenergy spectrometer (high-purity germanium (HPGe)gamma spectrometer) It is an instrument used for low-level gamma radio activity spectral measurement, which can accurately and qualitatively measure the conducting/performing of samples containing gamma radio activity without loss

  • AVATAR-GS Dual-Channel Gaussian MCA

    The AVATAR series dual channel Gaussian digital MCA spectrometer is based on a fully automated spectrometer system, which has been formed into a series of products. From the perspective of acquisition performance, it can be divided into basic performance and high count rate performance

  • NUWA Desktop MCA (Sipper MCA)

    1) Introduction: Sipping MCA is a 100% domestically manufactured digital MCA system developed by Jiechuan Nuclear Instruments (Beijing) Technology Co., Ltd. It is an internally integrated digital MCA system that requires a signal polarity adjustment unit